Product description
The next generation of Conductive Anodic Filament Monitoring equipment used to measure the influences of sub-surface electro-chemical reactions, the AutoCAF2+™ .
AutoCAF2+™ is able to measure up to 256 individual measurement sites under conditions of high humidity and temperature in accordance with IPC-TM-650 2.6.25 Test Method & IPC 9691 CAF Test Users Guide.
Conductive anodic filament (CAF) failure is copper corrosion within a printed board. It is electro-migration of the copper from Anode to Cathode between two conductors of different potential, whereas growth from Cathode to Anode is a dendrite.
A combination of bias voltage and high humidity enhance CAF failures. Electrical failure results when a filament grows between electrically isolated nets. See IPC-9691 for further information on CAF.
The NEW AutoCAF2+™ was developed in conjunction with a major CAF research project conducted by the British NPL.
Key Features
- Measurements from all 256 Channels can be taken in <30 seconds
- Applied Voltage: +1V to 1250V
- Measurement Range: 106 Ω to 1014 Ω
- Measurement Method: Continuous on all selected channels
- Measurement Test Intervals: Fully selectable from a minimum of 1 minute
- Capable of testing to all existing test specifications – IPC – IEC – JNC and other user specifications
- Future proofed design
- AutoCAF2+ is available with 64, 128 or 256 channel configurations
- Adaptable and flexible software operating with Windows 7, 8 &10.