Photo from the approved catalog (CAT-ASI-MN2 Rev. 01). Machines on a white background with the ASI logo.
Modular PSA Nitrogen Generators
16 models, 2.2 to 60 Nm³/h at 99.999%, and up to 220 Nm³/h at 99%.
The ASI-MN2 series generates nitrogen on site from clean compressed air by pressure swing adsorption (PSA) on carbon molecular sieve, with two adsorption towers working alternately for a continuous supply. Every unit has a built-in N₂ buffer tank, PLC control, a continuous oxygen analyzer and a touch screen.
ASI_MN2-Series_CAT_Rev01_2026-11-16.pdf
The first nine uses are the applications named in the series catalog. They are followed by further on-site PSA nitrogen uses confirmed from external sources; these uses are not listed in the catalog. Application data are typical industry values, not a process guarantee.
Inert oven atmosphere reduces oxidation and improves wetting. Typically 99.9% to 99.99% N₂ (1000 to 100 ppm O₂), and 50 ppm or less for demanding work.
N₂ over the solder pot cuts dross and improves wetting. Typically 99.9% to 99.99% (about 100 ppm O₂).
N₂ shrouds the nozzle to keep the mini-wave clean and limit dross. Typically 99.99% to 99.999%.
Dry N₂ purge holds moisture-sensitive parts at 5% to 10% RH or less (IPC/JEDEC J-STD-033) and limits oxidation.
N₂ assist and shield gas gives bright, oxide-free edges. Typically 99.9% to 99.999%; cutting needs a booster for high pressure.
Inert build chamber protects the melt pool and powder. Typically 99.99% (100 ppm O₂ or less); argon for titanium.
N₂ furnace atmosphere prevents scaling and discoloration in annealing and brazing. Typically 95% to 99.999%.
N₂ replaces oxygen in the pack to extend shelf life. Typically 99% to 99.9%.
Blanketing, inerting and packaging at 99% to 99.999%; LC-MS and sample evaporation at 95% to 99.5%.
Nitrogen is used to inert and blanket tanks to limit oxidation, and to sparge wine to reduce dissolved oxygen, including during transfer and bottling.
Breweries and beverage plants use nitrogen for tank blanketing and headspace purging, and sometimes to add nitrogen to the drink, to limit oxygen exposure.
Nitrogen is used for tank blanketing, pipeline purging, pressure testing and enhanced recovery, to provide an inert atmosphere and reduce moisture and oxidation.
Nitrogen blankets and inerts the headspace of storage and process tanks, to reduce fire risk and prevent oxidation of sensitive chemicals.
Dry nitrogen is used to inflate tires, especially on aircraft and heavy equipment, as a drier and more stable gas than compressed air.
In gas-assisted injection molding and related processes, nitrogen is injected into the part; it is also used to blanket stored resin to limit oxidation and defects.
The first nine photos were cropped from page 2 of the approved catalog (CAT-ASI-MN2 Rev. 01), originally from Wikimedia Commons; third-party brand marks had already been removed in the catalog. New-use photos were cropped to the same aspect ratio.
0.7–1.0 MPa supply
0.3 m³ recommended for ASI-MN2-5 and -8; other models on request
Removes water
Dust and oil removal
Towers A / B and N₂ buffer tank
Reflow, soldering, laser
Compressed air is dried and filtered before the ASI-MN2 separates N₂ in towers A / B; the built-in buffer tank feeds the point of use. Upstream equipment is not included.
| Model | 99% | 99.9% | 99.99% | 99.995% | 99.999% |
|---|---|---|---|---|---|
| ASI-MN2-2.2 | 8.1 | 5.4 | 3.5 | 2.9 | 2.2 |
| ASI-MN2-5 | 19.2 | 11.4 | 7.8 | 6.4 | 5 |
| ASI-MN2-8 | 28.8 | 17 | 11.7 | 9.9 | 8 |
| ASI-MN2-10 | 38 | 23 | 15 | 13 | 10 |
| ASI-MN2-13 | 48 | 27 | 19 | 16 | 13 |
| ASI-MN2-16 | 57 | 39 | 23 | 19 | 16 |
| ASI-MN2-18 | 67 | 43 | 26 | 23 | 18 |
| ASI-MN2-21 | 76 | 45 | 30 | 25 | 21 |
| ASI-MN2-23 | 86 | 51 | 35 | 29 | 23 |
| ASI-MN2-26 | 96 | 57 | 40 | 33 | 26 |
| ASI-MN2-30 | 110 | 65 | 45 | 38 | 30 |
| ASI-MN2-37 | 134 | 80 | 55 | 46 | 37 |
| ASI-MN2-42 | 152 | 90 | 65 | 52 | 42 |
| ASI-MN2-48 | 172 | 102 | 70 | 58 | 48 |
| ASI-MN2-54 | 192 | 114 | 80 | 66 | 54 |
| ASI-MN2-60 | 220 | 130 | 90 | 76 | 60 |
| Model | N₂ outlet | Air inlet | L×W×H mm | kg |
|---|---|---|---|---|
| ASI-MN2-2.2 | Φ8 | Φ16 | 580×500×1690 | 140 |
| ASI-MN2-5 | Φ8 | Φ16 | 745×500×1690 | 200 |
| ASI-MN2-8 | Φ8 | Φ16 | 907×500×1690 | 280 |
| ASI-MN2-10 | Φ8 | Φ16 | 1070×500×1690 | 340 |
| ASI-MN2-13 | Φ8 | G3/4 | 1230×500×1690 | 410 |
| ASI-MN2-16 | Φ12 | G3/4 | 1390×500×1690 | 480 |
| ASI-MN2-18 | Φ12 | G3/4 | 1560×500×1690 | 560 |
| ASI-MN2-21 | Φ12 | G1 | 1720×500×1690 | 620 |
| ASI-MN2-23 | Φ16 | G1 | 1880×500×1690 | 710 |
| ASI-MN2-26 | Φ16 | G1 | 2040×500×1690 | 830 |
| ASI-MN2-30 | Φ16 | G1-1/4 | 2200×500×1850 | 900 |
| ASI-MN2-37 | Φ16 | G1-1/4 | 1710×990×1690 | 1230 |
| ASI-MN2-42 | Φ16 | G1-1/2 | 1870×990×1690 | 1450 |
| ASI-MN2-48 | G3/4 | G1-1/2 | 2030×990×1690 | 1600 |
| ASI-MN2-54 | G3/4 | G1-1/2 | 2190×990×1690 | 1800 |
| ASI-MN2-60 | G3/4 | G1-1/2 | 2350×990×1850 | 2000 |
| Feed gas | Clean compressed air, 0.7–1.0 MPa (optimum about 0.8 MPa) |
|---|---|
| Air quality | ISO 8573-1:2010 class 1-4-1; dew point ≤ 2–10 °C; oil ≤ 0.01 mg/m³ |
| Air demand | > 0.6 Nm³/min (ASI-MN2-5); > 1 Nm³/min (ASI-MN2-8); other models on request |
| Outlet pressure | 0.6 MPa (ASI-MN2-5 and -8, with 0.1 MPa drop at the inlet); other models on request |
| N₂ buffer tank | Built-in in every model; no extra N₂ tank required |
| Monitoring | Flow meter (L/min), continuous oxygen analyzer (ppm), N₂ sampling port |
| Control system | Siemens PLC, pneumatic program valves, touch screen (English) |
| Power supply | 220V / 200W / 50Hz |
| Site | 10–35 °C, clean, dry and ventilated; 0.5 m clearance above the unit; ratings at altitude 0 m |
| Required upstream equipment (not included) | Air compressor, air tank, refrigerated dryer, three-stage filtration, then the generator |
| Air tank | 0.3 m³ recommended for ASI-MN2-5 and -8; other models on request |
| Maintenance, filters | Air filter element 4000 h; precision filters 4000–8000 h; N₂ filter element 1 year |
| Maintenance, wear parts | Silencers (2) 1–2 years; pressure relief valves (2) 2 years; activated carbon 5–10 years |
| Ordering | Model ASI-MN2- |
Specifications are subject to change without notice. Document CAT-ASI-MN2, Rev. 01, 16 Nov 2026.
Looking for the most suitable solution? Contact our experts